| INTERLECTIVE
DIGITAL METER |
 |
MS2301
EARTH RESISTANCE CLAMP
Earth
resistance clamp is a breakthrough from traditional tester.
Neither the supplementary earth leads nor the break earth equipment
is necessary. Ground resistance result can be get safe and fast
only by clamping the ground line.Additionally, current testing
is also provides. High sensitivity clamp meter can measure the
leakage current to 1mA, neutral current to 30A RMS. It is especially
important for testing ground circuit with strong interference
and ripple that will influence the electrical quality.Besides
industrial electronic equipment, it is also widely used in the
field of electric power distribution, telecommunication and
architectural ground.
|
Technical
Specifications
| RESISTANCE |
RANGE |
ACCURACY |
RESOLUTION |
0.01
– 0.999 |
±
(1.5%+0.01 ) |
0.001
 |
1
– 9.99 |
±
(1.5%+0.1 ) |
0.01
 |
10
– 99.9  |
±
(2.0%+0.3 ) |
0.1
 |
100
– 199.9  |
±
(3.0%+1 ) |
1
 |
200
– 400 |
±
(6.0%+5 ) |
5
 |
400
– 600  |
±
(10 %+10 ) |
10 |
600
-1200  |
- |
- |
| 100mA |
±
(2.5%+1mA) |
0.1mA |
| 300mA |
±
(2.5%+2mA) |
0.3mA |
| 1A |
±
(2.5%+3mA) |
0.001mA |
| CURRENT |
3A |
±
(2.5%+0.03mA) |
0.003mA |
| 10A |
±
(2.5%+0.03mA) |
0.01mA |
| 30A |
±
(2.5%+0.05mA) |
0.03A |
|
 |
M97
SEPARBLE DIGITAL CLAMP METER
Auto-ranging on all function
The LCD display is 3200 counts Max. And 33 segments bar graph.
|
Technical
Specifications
| DC
Voltage |
-
0.3/3/30/300/600V 0.7% |
| AC
Voltage |
-
3/30/300/600V 0.8% |
| Resistance |
-
300 /3k /30k /300k /3M ±1.2%
30M ±2.0%
|
| Diode
test |
| Back
light |
| Continuity
check: Built in buzzer will sound. |
| Data
hold |
| Auto
power off |
|
 |
M97A
The AC current transducer has been designed
according to EC-1010-2-032 concerning safety requirement for
hand-held current clamps for electrical measurement and test.
It is used with M97.
|
Technical
Specifications
| AC
current |
-
below 50A±3.0%, 50A~300A±2.0% |
| Max.
jaw opening |
-
30mm |
| Dimension
|
- 81
x 106 x 31mm |
| Weight
|
-
Approx. 130g. |
|
 |
M97C
THERMOCOUPLE MODULE
|
Technical
Specifications
| Imput
|
-
K
- type thermocouple |
| Centigrade |
-
- 50~- 20 °C ±2.0%, - 19~350 °C ±0.5%
351~500 °C ±2.0%, 501~1000 °C ±2.9%
|
| Fahrenheit |
-
-58~-4 °F ±2.0%, -3~662 °F ±0.5%,
663~932 °F
±2.0%, 933~1832 °F±2.9%
|
| Fahrenheit |
-
58~-4°F ±2.0%, -3~662°F ±0.5%, 663~932°F
±2.0%, 933~1832°F±2.9%
|
| Power
|
-
6F22(9V) X 1 |
| Size |
-
85 x 51 x 30mm |
| Weight
|
-
Approx. 110g (Include battery) |
| Output
Voltage |
-
1mV dc/ °C, 1mV dc/ °F |
|
 |
MS9912
|
Technical
Specifications
| Display |
-
Digital and analog display 3200 counts and 33segment bar
graph,digit is. 15mm high
|
| DC
Voltage |
-
3/30/300V ±0.8%, 1000V ±1.0% |
| AC
Voltage |
-
3/30/300V
±1.0%, 750V ±1.2% |
| DC
Current |
-
300/1000A<600A ±2.0%, >600A 3.0% |
| AC
Current |
-
300/1000A<600A ±2.0%, >600A 3.0% |
| Max.
Diameter for conductor |
-
50mm |
| Resistance |
-
300/3k/30K/300K/3M
±2.0%
30M ±2.5%
|
| Frequency |
-
30kHz ±2.0% |
| Diode
test |
| Data
hold |
| Continuity
test |
| Autorange
and Manual range |
| Back
light |
| Power
|
-
6F22 (9V) x 1 |
| Size
|
-
282 x 104 x 47mm |
| Weight
|
-
Approx. 550g. |
|
Next |
 |